| Fully Automated Coagulation Analyzer We offer Fully Automated Coagulation Analyzer. - Test method: double magnetic route
- Sample consumption: < 200uL
- Reagent consumption: 50uL~200uL
- Temperature: 37°C±0.5°C
- Adding sample: by a timing linkage
- Precision: ±10%; CV<10%
- Speed: <300s(depend on setting)
- Channel: 4/2/1
- Sample warming up position: 16/8/8
- Reagent warming up position: 6/6/6
|
 
FTIR/FTNIR Spectrometers FTIR spectrometer 2201 is a low cost easy to use laboratory instrument designed for a wide range of IR spectroscopy applications. Basic accessories for IR studies, such as different types of liquid cells, gas cells, including longpath, specular reflectance accessories, HATR kit, etc. are available. The basic software package is Windows 9x/Xp based. Specifications | Model | FTIR 2201 | FTIR 2202 | FTNIR 2203 | | Spectral range, cm-' | 400-7800 | 400-7800 | 2500-12000 | | Spectral resolution, cm-' | fl111flBH | 0.5 | 2 | | Signal/Noise ratio RMS (resolution 4 cm-', 1 min) | >20000 | | Minimum scan time (resolution 4 cm-'), sec | | | Sample compartment dimensions, cm | 15x19x17 | | Spectrometer dimensions, cm | 52x37x25 | | Weight, kg | 28 | Main Feature - Permanent Alignment: Interferometer provides long-time stability and requires no alignment due to design, utilising cube corner retroreflectors.
- Sealed Housing: Interferometer and detector sections including control electronics are enclosed in hermetically sealed aluminium housing. The enclosure is dessicated to eliminate atmospheric interference.
- Original Scanning System: Mirror movement is digitally controlled. Scanning mechanism utilising a precision plain bearing is pressurised air free.
- Air Cooled IR Source: IR source needs no cooling water. Replacement procedure is simple and does not require any alignment.
| |
 
| Fully Automatic Hematology Analyzer We offer Fully Automatic Hematology Analyzer Specifications - 23 parameters, with 3 part WBC differential
- 10 uL sampler volume
- Memory of 30,000 results including histograms
- Throughput: 35 samples/hour
- Automatic and manual calibration
- Automatic dilution when power on/off
- High voltage cleaning after each measurement
- QC mode: X-B, L-J curve, SD, CV
|
 
Microplate Reader We offer Microplate Readers: - Spectrum Range: 400~750mm
- Standards Wavelengths: 405nm, 450nm, 492nm, 630nm
- Optional Wavelengths : 414nm, 546nm, 578nm, 690nm
- Microplate: 96-well plate with flat bottom (recommended)
- Measurement Range: 8-Channel optical fibre system
- Light: 8V/50W Halogen lamp
- Read range: 0.000-4.000A
- Linearity: ±1.0%
- Resolution: 0.001Abs
- Accuracy: ±1%or0.01(A)
| |
 
| Urine Analyzer We offer Urine Analyzer Specifications - 23 parameters, with 3 part WBC differential
- Aperture Diameter 70um
- 10 uL sampler volume
- Memory of 30,000 results including histograms
- Throughput: 35 samples/hour
- Automatic and manual calibration
- Automatic dilution when power on/off
- High voltage cleaning after each measurement
- QC mode: X-B, L-J curve, SD, CV
|
|
 |