With the support of adept workforce, we design and develop wide assortment of industry standard biotech instruments. These are offered in various technical specifications and designs to meet the specific requirements of our client. Our UV-VIS spectrophotometer finds application in determination of nutrients including N, P, K, S, Ca and others and organic components present in plants and agricultural soil. Our precision engineered flame photometer efficiently measures the concentration of alkali & alkali earth metals in geological & agricultural soil testing, food & beverage testing and others. Wide range of instruments offered by us includes:
|
 
| Atomic Absorption Spectrophotometer  We are one of the leading manufacturers and exporters of highly efficient atomic absorption spectrophotometer. These are offered to our clients with customized solution as per their technical specification. Modes of operations of the instrument include absorbance, concentration, standard addition & emission. The range is stringently checked by our quality team prior to its dispatch at client end. Features of atomic absorption spectrophotometer include: - Microprocessor based, user friendly, menu driven, with printer interface
- Optional PC Compatibility with RS 232C Interface and MS Windows® based Software for data acquisition, processing, storage, retrieval & interpretation of data
- Continuous source background correction
- Quick change and easy alignment of hollow cathode lamps with standby warm-up facility
- Precise vertical, lateral and rotational alignment of Titanium Burner
- Optimal parameters storable in built-in memory
- Self diagnostic
| Spectral | | Range | 190 to 900 nm | | Accuracy | ± 0.5 nm | | Bandwidth | 0.15 to 3.0 nm variable in steps of 0.15 nm | | Photometric | | Range | 0 to 2 Abs | | Accuracy | ± 0.01 Abs at 1 Abs | | Integration Time | 0.04 to 99 Sec | | Light Source | Hollow Cathode Lamp (HCL)* | | Background correction | Deuterium Lamp (D2)* | | Burner | Titanium Construction Premix, Laminar flow, 100 mm | | Fuel | Acetylene (C2H2) | | Oxidant | Air/Nitrous Oxide (N2O) | | Flow Control | Integral gas control system with panel flow meters | | Nebulizer | Pneumatic, with 90% Platinum, & 10% Iridium alloy Capillary* | | Sample Feed Rate | 3 to 8 mL/min (Adjustable) | | Monochromator | Czerny Turner 300 mm with 1200 lines/mm Holographic diffraction grating & Hard coated optics | | Slits | Bilateral continuously variable of 0.15 to 3.0nm spectral bandwidth | | Detector | Wide Range Photomultiplier tube (PMT) | | Readout | 24x2 Dot matrix LCD panel with backlight of 2.70 x 5.5mm character size | | Power Supply | | HC Lamp | 0 to 30 mA, modulated | | D2 | 15 to 300 mA, modulated | | PMT | -200 to -1000 V | | Power requirement | 230 V ± 10%, 50 Hz, 1 , Max. 200 VA | |
 
Biochemistry Analyser We offer Biochemistry Analyser Designed to Test - Therapeutic drug
- Co – Aggulation
- Electrolytes
- Substrates
- Enzymes
Specifications Methods - Absorbance
- Mono – ChromaticTechnical
- Bi – Chromatic
- End Point with standard / factor
- Fixed Time Kinetics
- Mutipoint Kinetics
- Multi Standard up to 8-Standards
Measurement Apparatus - Removable Cuvettes Semi – Micro and Micro
- Silicon Photodiode
Specifications Methods - Absorbance
- Mono – ChromaticTechnical
- Bi – Chromatic
- End Point with standard / factor
- Fixed Time Kinetics
- Mutipoint Kinetics
- Multi Standard up to 8-Standards
Optical System - Principle Photometry
- Range of measurement
- From 0 – 2.5 A for 340 nm
- From 0 – 3.0 A for 405 nm & upwards
- Automatic Zero Setting
- Halogen Lamp 12V 20W
- Spectral range selection:Automatic via filter wheel
Display and Keyboard - Blue Screen 4x20 LCD
- PCB Optimized Membrane Keypad
Memory Storage Capacity Filters (nm) - 340, 405, 505, 546, 578, 630
- Plus Two Optional filter
- Bandwidth : 10nm (+ 2nm)
Power / Dimensions - Voltage 220 V
- Frequency 50 Hz.
- Temperature : 25 oC, 30 oC, 37oC
- Max. Relative Humidity 75%
- Dimensions : 33 x 32 x 12.5 cm
- Weight : 7 kgs
- Max. Power : < 100VA
Optional Interface - External Dot Matrix Printer
- RS 232 Interface
Thermostat System - Thermostat controls
- 25oC, 30oC, 37oC
- Accuracy : + 0.1oC
Inbuilt Thermal Printer - Graphic Thermal Printer.
- Characters per line – 384 Dots / Line.
- Thermo – Sensitive – 57mm Wide Paper
| |
 
| Biotechnology Teaching Aids / Bio-Chemicals We offer a wide range of Biotechnology Teaching Aids. These are available in form of biotechnology teaching kits, bio-chemicals & tech-ware. The process expertise of our team also allow us to meet the application demands of fields like genomics, proteomics, Electrophoresis, molecular biology, Protein purification and analysis. These can also be custom designed and manufactured as per the specific demands of the clients. |
 
BOD Test Kit Biochemical Oxygen Demand (BOD) test aims to determine the concentration of oxidizable and biodegradable organic compounds in water. The test most often runs for a five day period. Its widest application is in measuring waste loading of treatment plants, and in evaluating the efficiency of treatment processes. CheckLight scientific development team has developed a unique technology for determination of BOD in water in only 3-4 hours.
Features -CheckLight BOD Test : -
Principle- The tested water sample is pre-hydrolysed with acid and exposed to the bacteria. The obtained level of luminescence reflects the concentration of utilizable organic carbon compounds in water. Bioassay - Freeze-dried luminous bacteria.
Fast - Results are obtained within 3-4 hours.
Sensitive - A vast range of organic compounds can be detected at a wide concentration range.
User - friendly - Minimal lab experience is necessary. A simple three-step procedure. Only 1mL of sample is necessary to run the assay, making collection, storage and disposal of sample material easy and cheap Equipment - CheckLight luminometer, pipettor, tips.
Reliable - Good correlation was obtained against the standard BOD test for a given water source.
Cost effective - Low price encourages more frequent monitoring of treatment plant efficiency and allows rapid response to changing conditions. | |
 
| Brookfield Viscometers With our industrial experience gained in a decade, we develop high performing brookfield viscometers. These are designed and fabricated in compliance with the global standard. In addition, it is also offered as per the technical specifications provided by our clients. It finds application for measurement of viscosity at high shear rates. It uses less than 2 ml of sample and thus helps in avoiding excess cleaning and material costs. Other features of our brookfield viscometers include following: - LCD display of viscosity in Poise or Pascal-seconds
- Automatic viscosity range calibration and cone gap positioning make the viscometer easy to use
- Set the viscometer to take a reading at different timed intervals to ensure accuracy of results with thixotropic fluids.
|
 
Colorimeter We specialize in designing and manufacturing precision engineered colorimeter in compliance with industry standard. The instrument is also developed as per the client specifications and requirements. It is highly in demand in laboratories, clinics and pharmaceutical industry for determining concentration of constituents in medical institute, textile industry and others. It also finds application in food, beverage & water analysis. In addition, it is also used in analytical & agricultural chemistry and metallurgy. Features: - Stable, Direct Readout of Absorbance
- Compact & Easy to operate
- Rugged, Sturdy & Reliable
- Thumb Wheel Selection of Filters
- Pre-focused Light Source
- Long Life Photo Diode Detector
- Only 1 ml of Sample need
- Usable for Disposable cells
Specifications: | Photometric | | Range | -0.1 to 1.99 Abs | | Repeatability | ± 0.01 Abs | | Stability | ± 0.01 Abs in 8 h | | Light Source | Tungsten Lamp | | Filters (8) | Peak Transmission at 450, 470, 490, 520, 540, 570, 600 & 670 nm | | Shutter | To prevent the detector from continuous exposure to light | | Detector | Photo diode | | Readout | 2½ Digit 7 segment LED display of 12.7mm height | | Power Requirement | 230 V ± 10%, 50 Hz, 1 , Max. 20VA | | Physical Dimensions | | Size (WxDxH) in mm | 270 x 180 x 110 | | Weight in Kg. | Approx. 3.0 | | Accessories Supplied | | With Instrument | Matched 3 mL test tubes, holder for 10mm path length glass cuvettes disposable cells | | At Extra cost | Glass cuvettes & disposable cells | | |
 
| Digital Potentiometer Our company offers compact designed potentiometers to our clients. Fabricated in compliance with the international standard, the range is globally accepted for its high performance. Our assortment is used for potentiometeric measurements. Results of the instrument are displayed by light emitting diodes (LED) in milli volts on a direct digital readout.
Specifications: | Range | 0 to+ 1999.9mV | | Resolution | 1 mV | | Repeatability | + 1 mV | | Accuracy | + 1 mV +digit | | Input Impedancy | 10 ohms | | Operating Temperature | 10 to 50oC | | Display | 3 1/2 Digit 0.5 seven segment LED display Indication | | Power | 230V + 10?, 50Hz | | Dimensions | 76 x 275 x 170 mm. | | Weight | 2 Kg (approx.) | | Standard Accessories | | Electrode | 2 Nos. | | Dust Cover | 1 No. | | Electrode Stand | 1 No. | | Manual | 1 No | |
 
Digital Turbidity Meters Our digital turbidity meters are globally known for giving reliable and accurate results. The digital turbidity meter is fitted with 3 ½ digit LED Display which can measure upto 1000 JTU. It finds applications in sewage and drinking water testing. Our collection is acknowledged for defect free structure, dimensionally accurate and light in weight.
Measurement: | Range | 0 to 200 JTU 0 to 1000 JTU 2 Ranges | 0 to 20.00 NTU 0 to 200.00 NTU 2 Ranges | | Resolution | 1 JTU | 0.1, 1 NTU | | Accuracy | +3% FS + 1 digit | +2% FS + 1 digit | | Sample System | 30 mm clear glass tube | 30 mm clear glass tube | | Light Source | 6.8 V, Tungsten Lamp | 6.8 V, Tungsten Lamp | | Detector | Photodiode | Photodiode | | Display | 3 1/2 digit LED display | 3 1/2 digit LED display | | Power | 220V+ 10% AC 50 Hz | 220V+ 10% AC 50 Hz | | Size (LxBxH) | 305 x 305 x 165 mm | 305 x 305 x 165 mm | | Weight | 4 kg (approx.) | 4 kg (approx.) | | Accessories | Test Tube Set, Operation Manual & Dustcover | | Other Models | Analog Nephelometer Battery cum Mains Operated also Available | | |
 
| Dissolution Tester We offer Dissolution Tester. Our tablet dissolution test apparatus is developed from grade raw material. With the support of our proficient team, the apparatus is designed and manufactured as per the USP Standard. Featured with defect free structure, dimensionally accurate and light in weight, the apparatus is widely accepted by our reputed clients. It efficiently works for single tests of capsules or tablets. |
 
Electrophoresis Unit We offer Electrophoresis Unit. We specialize in designing and manufacturing precision engineered horizontal gel electrophoresis unit. Backed by our proficient team, we develop the unit as per the industry standard. It is specially designed for analysis of 10 samples and 1 marker. A gel-casting tray of size 110mm x 90 mm along with an 11 well comb are provided the horizontal unit. Other accessories including a safety lid and electrical connectors are also offered with it. | |
 
| Flame Photometer Our flame photometer is globally appreciated for its features including dimensionally accurate, compact designs, easy operation and heat resistant. The instrument is developed using grade raw material and technology. It is available to our clients in customized packaging ensuring scratch free flame photometer dispatched at client end. Features: - Dual Channel
- Concentric Non-corrosible Nebulizer
- Mixing Chamber designed for stable flame
- Flame System: Stainless Steel round burner with LPG as Fuel & Air as Asoxidant and stainless steel needle type regulator
- Narrow Band interference Filters
- Small quantity of sample needed
Applications: It finds applications for measurement of Concentration of Alkali & Alkali earth metals (Sodium, Potassium, Calcium & Lithium) in geological & agricultural soil testing, pollution monitoring & control, food & beverage testing and cement. In addition, it is also used to measure the concentration of the alkali and alkali metals in coal, chemicals, ash, fuel & greases, crude oil, glass, acids, pharmaceutical and other industries. |
 
HPLC System Our HPLC System is precisely engineered in conformity with global standard. It is widely acknowledged for dimensionally accurate, compact designs, easy operation and heat resistant. Our collection finds wide application in laboratory, research institute and many others. Isocratic Pump. Following are the technical specifications of isocratic pump: - Flow: 0. 01-10mL/min / 0.001-9.999
- Max. Pressure: 40MPa
- Dual Piston designed with main and auxiliary pump heads connected in series Intuitive operating using simple keypad allows easy chose functions as follow:
- Flow rate
- Maximal flow rate – PURGE (for priming and washing)
- Low pressure
- High pressure limit
- Pulsation compensation on-off
- Pressure unit (PSI,Mpa or bar)
- Control mode (by keypadm RS 232 or using voltage)
- Display brightness
- Possibility to use this pump by high pressure gradient mode, where are two three or four unit controlled from PC using RS232 or voltage.
| |
 
| Melting Point Apparatus Melting Point Apparatus is designed for quick and accurate detection of melting point. Feature packed & easy to use, this is an indispensable bench top tool. This equipment has an arrangement to hold the capillary containing the sample in uniformly heating media. the temperature is indicated on a digital display readable in 1.0oC. At the point, whn the sample melts, the heating is automatically cut-off and the digital display showing the temperature remains on the indicator till it is cleared. No Silicon oil or other bath is required as heating media. Range 2.0oC above room temperature to 350oC. Salient Feature - Fully Automatic
- Latest Technology
- Range upto 350oC
- Highly Accurate
- No Silicon Oil/ Heating Media Required
Specification :- | Display | Digital 3 ½ Digit, Bright LED | | Accuracy | 1% | | Operation | Fully Automatic | | Dimensions | L 405 x B 360 x H 235 mm (approx) | | Weight | 5 Kg (approx.) | | Power | 230V + 10?, 50Hz | | Accessories | Capillary Tube - 100 No., Cleaning Tool - 1 No. | |
 
Moisture Titrator We design and fabricate precision engineered Karl Fischer moisture titrator. Available in various specifications, the titrator can be customized in accordance with client requirements. Featured with compact designs, easy operation and efficiency, our assortment has received wide accolade in diverse industries. Specifications of our most advanced Karl Fischer moisture titrator are tabulated below: | Range | 0.1mg - 500mgH2O, 10ppm - 100%H2O | | Burette | Capacity 10mL x 2 Precision ±0.015mL | | Display | 30 digits x 7 lines LCD with back light | | External I/O | 1. Printer 2. Balance 3. Computer via RS232C | | Output | H2O, concentration, dialogue messages | | Ambient condition | 5 - 35°C, less than 85%RH | | Power | 100 -120/200-240V AC, 50/60 Hz | | Power consumption | 35W | | Dimension | Main: 288(W) x 468(D) x 629(H) mm Stirrer: 120(W) x 225(D) x 320(H) mm Solvent change unit: 240(W) x 170(D) x 405(H) mm | | Weight | 13.5kg | | |
 
| Photo Colorimeter We offer Photo Colorimeter Salient Features - 1 ml. Solution measurements
- Standard Glass Filters
- Highly Stable & Accurate
| Model | SI – 21 Analog Model | | Std. Glass Filter | 8 | | Mini Volume | 1 ml. | | Display | 125 x 100 mm Ammeter | | Range | 400-700 nm | | Output | OD (0 to 1.99) %T (0 to 100) | | Resolution | OD : 0.01 %T-1% | | Accuracy | 0.5% FSI | | Detector | Selenium Photocell | | Light Source | 6.8v, 300mA | | Power | 230v + 10% | | Accessories | Test Tube set of 5, Spare Lamp, Dust Cover, Manual | | Filters | 8 Filters - 400, 420, 480, 500, 520, 540, 620, 680 nm | |
 
Tablet Hardness Tester We specialize in designing and developing precision engineered tablet hardness tester. Our tester can be fitted on either bench or tablet ling machine. It is offered with various precision engineered components including engineered Dial Gauge, Aluminium Body and others. Follow pointer records force on Dial Gauge while main pointer goes back to zero. Specifications: - Capacity 0-200 Newtrons
- Accuracy + 5 Newtrons
| |
 
| Ultrasonic Bath (Sonicator) We offer Ultrasonic Bath (Sonicator) Salient Features - Easy to operate & made of one piece S. S. Tank
- Indigenously manufactured with advanced MOSFET technology, with
- Auto-tuning facility
- Compact, rugged and highly durable systems
- Extensively protected electronic circuits means longer and safer operations
- Digital tuning of Transducers with Generators to avoid any frequency shifted even during demanding applications
Technical Specification - Operating frequency 33+3KHz, for all general purpose cleaning is highly recommended
- Input Voltage range of 170V AC - 270V AC, 50Hz, 1Ph
- Micro Controller based timer range 0 to 30/99 minutes
- Thermostatic controlled temperature controller
| Capacity | Tank Size (LxBxH)mm | Overall Dimension (LxBxH)mm | Wattage | | 1.5Lit | 240x135x65 | 265x160x180 | 60W | | 3.5Lit | 300x150x100 | 330x175x250 | 120W | | 6.5Lit | 300x150x150 | 450x200x350 | 200W | | 9Lit | 300x200x150 | 450x300x375 | 250W | |
 
UV-VIS Spectrophotometer Our company offers wide range of UV-VIS spectrophotometer which is fabricated in conformity with international standard. The collection is also designed and developed in accordance with the client specifications and requirements. It finds application in laboratories, research institutes, textile & leather industry and many others. Following are the features of our compact UV-VIS spectrophotometer: - Microcontroller based
- High Signal to Noise ratio
- Stable single beam optics
- Push button selection of % T, Abs & Conc.
- Compact, Modular & ergonomically designed
- Simple selection of four position sample holder
- Accommodates cuvettes of upto 40mm path length Its applications are in determination of
- Nutrients like N, P, K, S, Ca, Mg, Zn, Cu, B, Mo etc., in Agricultural soil, plants and others
- Organic components in Plants and Biological matter
- Glucose, fructose, carbohydrates, proteins etc, in foods
- Edible dyes alcohols etc., in beverages
- Purity of constituents in pharmaceuticals
- Toxic elements Cd, Pb, Hg etc. in effluents
- Constituents in compositions used in metallurgy, fertilizer, pesticide, chemical, petrochemical, steel, cement, glass & other industries.
Specifications:
| Spectral |
| | Range | 190 to 1000 nm | | Bandwidth | 2 nm | | Accuracy | ± 0.5 nm | | Repeatability | ± 0.2 nm | | Readout | 4 digit 7 segment LED Display of 12.7 mm height | | Readability | 0.1 nm | | Photometric |
| | Range | 0 to 2 Abs | | Accuracy | ± 0.005 Abs. at 1.0 Abs ± 0.010 Abs. at 1.5 Abs | | Repetability | ± 0.002 Abs. at 1.0 Abs | | Stability | ± 0.003 Abs/hr. after 2 hr. warm up | | Stray light | < 0.1% T at 302 nm | | Readout of Abs., %T & C | 3½ digit 7 segment LED Display of 12.7 mm height | | Readability | ± 1 Count | | Light Sources | Deuterium(D2) & Tungsten (W) Halogen Lamps | | Monochromator | Czerny Turner with High resolution 1200 lines/mm Holographic Grating | | Detector | Wide range Photo Diode | | Power Requirement | 230 V ± 10%, 50 Hz, 1 ,Max. 150 VA | | |
 
| Water & Soil Analysis Kit We specialize in designing and fabricating superior quality water and soil analysis kit. It is made available to our clients with 3 ½ digit LCD Display. Our efficient kits are mains cum battery operated. It gives accurate result for soil and water analysis. Some of the salient features of our range: - Measures pH, mV, Conductivity
- TDS, DO, Temperature & Turbidity
- Housed in VIP Briefcase
Measurements: | Model pH | Range | SI - 60 | SI - 61 | SI - 62 | | 0 to 14pH | 0 to 14pH | 0 to 14pH | | Temp. Comp. | 0oC (Manual) | 0oC (Manual) | 0oC (Manual) | | Resolution | 0.01pH | 0.01pH | 0.01pH | | Accuracy | +0.01 pH | +0.01 pH | +0.01 pH | | O.R.P./mV | Range | N.A. | 0 to + 1999 mV | 0 to + 1999 mV | | Resolution | 0.01pH | N.A. | 1 mV | | Accuracy | N.A. | + 1 mV + 1 digit | + 1 mV + 1 digit | | Conductivity | Range | 1 | 5 | 5 | | Cell Constant | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | | Resolution | 0.1 Micro mhos | 0.1 Micro mhos | 0.1 Micro mhos | | Accuracy | + 0.5% FS | + 0.5% FS | + 0.5% FS | | Temperature | Range | 0o - 100oC | 0o - 100oC | 0o - 100oC | | Resolution | 0.1oC | 0.1oC | 0.1oC | | Accuracy | +0.1oC + digit | +0.1oC + digit | +0.1oC + digit | | T.D.S. | Range | 1 | 5 | 5 | | Cell Constant | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | 0.4 - 1.5 Adj | | Resolution | 0.1ppm | 0.1ppm | 0.1ppm | | Accuracy | +5% FSD | +5% FSD | +5% FSD | | D.O. | Range | 0-20 ppm | 0-20 ppm | N.A. | | Temp. Comp. | 0.1 ppm | 0.1 ppm | N.A. | | Resolution | +0.3 ppm | +0.3 ppm | N.A. | | Accuracy | 5o to 50o (Manual) | 5o to 50o (Manual) | N.A. | | Turbidity | Range | 0-1000 NTU/JTU | N.A. | N.A. | | Resolution | 1 NTU/JTU | N.A. | N.A. | | Display | Selenium Photocell | 3 1/2 digit LCD display | | Power Suppy | 6.8v, 300mA | 1.5V x 6 Dry Cells or 230V + 10% 50 Hz | | Accessories | 230v + 10% and In-built Battery | pH Combination Electrode, Conductivity / TDS Cell, DO Probe, Temp Probe, Standard Solution, D.O. Memberanes, Cell Container & Instruction Manual | | Product Range | Photo Colorimeters, Spectrophotometers, Digital pH Meters, Conductivity/TDS Meters, Turbidity Meters, Digital D.O. Meters, Water & Soil Analysis Kits | |
|
 |