| Environment Test Chamber  | Temperature Range : 20°C to 60°C | Accuracy : ± 0.2°C | | Humidity Range : 40% RH to 95% RH | Accuracy : ±2% RH | | Temperature Uniformity : ±1°C | Humidity Uniformity : ± 3% RH | - Temperature & Humidity Suitable for 25 °C& 60% RH, 40 °C & 75% RH, 30 °C & 65% RH
- Specially designed chambers to carry out stability studies at low humidity conditions such as 25°C & 40% RH, 40°C & 25% RH NMT, 30°C & 35% RH
Construction : The unit is a double walled chamber, with glass wool / PUF insulation. Interior is made of Stainless Steeland Exterior is either made of Mild Steel finished in powder coating paint (powder coating on both sides of the mild steel) or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forcedair circulation for uniform temperature. PU wheels for easy move ability. Intelligent Control System : The controlling system having is PLC Base and PC communication on Ethernet and data acquisition system complying with 21 CFR Part 11 Heating System : Long lasting stainless steel tubular heaters with s.s. fins. Humidity System : Humidity is by steam injection. Humidity system consist of boiler tank, which is fitted with two nos. of boiler heaters, one heater works as a stand by and automatic switch over to stand by heater if regular fails and give alarm.A water reservoir tank is connected to the boiler tank. DM water is preferred. A magnetic float switch provided for safety for boiler low level to cut off the its supply. Sensor : Temperature and Humidity transmitter 4-20mA used for measurement. Temperature in degree Celsius and Humidity in %RH with 0.1°C and 0.1%RH resolution. Cooling System : CFC free, the cooling system consists of hermetically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. Refrigerant 134A. Alarms : Audio and visual alarms are generated for temperature / humidity variation, utility failure. Safety : The unit is provided with safety devices for temperature, and humidity over shoot in case of malfunction. |
 
BOD Incubators | Temperature Range : 10 °C to 60°C | Accuracy : ± 0.5°C | | Temperature Uniformity : ±1.0°C | - Temperature Suitable for 18 -24°C, 20-25°C, 30-35°C, 35-37°C, 40-45°C & 55-60°C.
- Exterior made of Mild Steel and Interior made of Stainless Steel.
- Exterior and Interior made of Stainless Steel (S).
The unit is a double walled chamber, with glass wool / PUF insulation. Interior is made of Stainless Steel and Exterior is either made of Mild Steel finished in powder coating paint (powder coating on both sides of the mild steel) or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forced air circulation for uniform temperature. PU wheels for easy move ability. INTELLIGENT CONTROL SYSTEM : The controlling system having is PLC Base and PC communication on Ethernet and data acquisition system complying with 21 CFR Part 11. HEATING SYSTEM : Long lasting stainless steel tubular heaters with s.s. fins. SENESOR : Temperature transmitter 4-20mA used for measurement. Temperature in degree Celsius with 0.1°C resolution. COOLING SYSTEM : CFC free, the cooling system consists of hermetically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. Refrigerant 134A. ALARMS : Audio and visual alarms are generated for temperature variation, utility failure. SAFETY : The unit is provided with safety devices for temperature over shoot in case of malfunction. STANDBY SENSOR : When controlling sensor fails it automatically switch over to standby sensor. | Models | Capacity | Inner Chamber Dimension | External Dimension | Trays | | Exterior M.S. | Exterior S.S. | Cuft. | Liters | H x W x D (mm) | H x W x D (mm) | Nos. | | NEC 108RS | NEC 108RSS | 8 | 200 | 600 x 600 x 600 | 1340 x 750 x 1030 | 2 | | NEC 112RS | NEC 112RSS | 12 | 324 | 900 x 600 x 600 | 1650 x 750 x 1030 | 3 | | NEC 116RS | NEC 116RSS | 16 | 440 | 900 x 700 x 700 | 1650 x 850 x 1130 | 3 | | NEC 121RS | NEC 121RSS | 21 | 600 | 1200 x 700 x 700 | 1950 x 850 x 1130 | 4 | | NEC 128RS | NEC 128RSS | 28 | 800 | 1200 x 800 x 800 | 1950 x 950 x 1230 | 4 | | NEC 134RS | NEC 134RSS | 34 | 1000 | 1500 x 800 x 800 | 1800 x 1600 x 950 | 5 | | |
 
| Walk in Cooling Chambers  | Temperature Range : 2°C to 8°C | Accuracy : ± 0.5°C | | Temperature Uniformity : ±1.0°C | - Exterior made of Mild Steel and Interior made of Stainless Steel.
- Exterior and Interior made of Stainless Steel(S).
The unit is a double walled chamber, with glass wool / PUF insulation. Interior is made of Stainless Steeland Exterior is either made of Mild Steel finished in powder coating paint (powder coating on both sides of the mild steel) or Stainless Steel. The unit has full-length inner glass door and outside metal door with magnetic gasket and lock. The unit is provided with perforated Stainless Steel trays. Forcedair circulation for uniform temperature. PU wheels for easy move ability. INTELLIGENT CONTROL SYSTEM : The controlling system having is PLC Base and PC communication on Ethernet and data acquisition system complying with 21 CFR Part 11. Forced air circulation for uniform temperature, Safety thermostat, Hermetically sealed compressor, with electronic time delay to safe gaurd compressor. SENESOR : Temperature transmitter 4-20mA used for measurement. Temperature in degree Celsius with 0.1°C resolution. COOLING SYSTEM : CFC free, the cooling system consists of hermetically sealed compressor coupled with evaporation coil and condenser, safe guarded by time delay circuit. Refrigerant 134A. ALARMS : Audio and visual alarms are generated for temperature / humidity variation, utility failure. SAFETY : The unit is provided with safety devices for temperature over shoot in case of malfunction. STANDBY SENSOR : When controlling sensor fails it automaticallyswitch over to standby sensor. | Models | Capacity | Inner Chamber Dimension | External Dimension | Trays | | Exterior M.S. | Exterior S.S. | Cuft. | Liters | H x W x D (Mtr) | H x W x D+ 0.8 (Mtr) | Nos. | | NEC 2190R | NEC 2190RS | 190 | 5,400 | 2.00 x 1.36 x 2.00 | 2.12 x 1.48 x 2.12 | 24 | | NEC 2230R | NEC 2230RS | 230 | 6,400 | 2.40 x 1.36 x 2.00 | 2.52 x 1.48 x 2.12 | 32 | | NEC 2280R | NEC 2280RS | 280 | 8,000 | 2.00 x 2.00 x 2.00 | 2.12 x 2.12 x 2.12 | 24 | | NEC 2340R | NEC 2340RS | 340 | 9,600 | 2.40 x 2.00 x 2.00 | 2.52 x 2.12 x 2.12 | 32 | | NEC 2530R | NEC 2530RS | 530 | 15,000 | 2.40 x 2.50 x 2.50 | 2.52 x 2.62 x 2.62 | 48 | | NEC 2640R | NEC 2640RS | 640 | 18,000 | 2.40 x 2.50 x 3.00 | 2.52 x 2.62 x 3.12 | 48 | |
 
Laboratory Plasticwares We specialize in designing and manufacturing export quality Laboratory Plasticwares. It is fabricated from grade polypropylene which is sourced from authoritative suppliers. The flask is rigid, autoclavable and translucent. The cone shaped flask is offered with the screw cap which keeps the contents of the Laboratory Plasticwares contamination free. The cap makes the flask leak proof. Prior to autoclaving, threads should be detached. The flasks are available to our clients in different capacities including 100ml, 250ml, 500ml and 1000ml. "We cover the entire range of the lab instruments for school/colleges, for more details please visit our website" | |
 
| Laboratory Glasswares We offer a wide range of laboratory glassware and plastic ware like laboratory beakers, laboratory flasks which are made of glass, plastic etc and are used for scientific experiments. These are transparent, heat resistant and easy to customize. Moreover, our range is widely used for a wide variety of functions like volumetric measuring, holding or storing chemicals or samples, mixing or preparing solutions or other mixtures, containing lab processes like chemical reactions, heating, cooling, distillation and for many other purposes. |
|
 |
|
 |
 |